3 pha; 380...500VAC; 22kW; 44A; 590Hz
Giá: Liên hệ
Mã hàng: FR-A840-22K-2-06
Hãng sản xuất: MITSUBISHI
Series: FR-A800 series
Category: Biến tần
- ĐẶC ĐIỂM
- TÀI LIỆU
- SẢN PHẨM CÙNG SERIES
- CATALOG
3 pha
|
||
380…500VAC
|
||
22kW
|
||
44A
|
||
590Hz
|
||
FR-BU2
|
||
FR-HEL
|
||
FR-ABR
|
||
Biến tần
|
||
50Hz, 60Hz
|
||
56.5A
|
||
380…500VAC
|
||
Băng tải, Cần trục, Quạt, Máy ép, Máy in, Bơm, Shield machines, Máy th áo sợi, Máy cuộn chỉ, Đốn gỗ, Sản xuất sản phẩm kim loại, Máy sản xuất giấy, Pulp, Ngành thép, máy dệt, Lưu trữ kho, Vận tải thủy, Máy làm gỗ, Ngành công nghiệp xây dựng, Lâm nghiệp […]
|
||
Biến tần tiêu chuẩn
|
||
120%
|
||
150%
|
||
Có tích hợp
|
||
Có tích hợp
|
||
No
|
||
12
|
||
1
|
||
1
|
||
6
|
||
2
|
||
2
|
||
1
|
||
High carrier frequency PWM control (V/f. Advanced magnetic flux vector control. real sensorless vector control. optimum excitation control), PM Sensorless vector control, Soft-PWM control, V/f Control, Vector control […]
|
||
Inverter overload trip, Motor overheat trip, Overcurrent trip during a cceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Heatsink overheat, Instantaneous power failure, Brake transistor alarm detection, Input phase loss, Loss of synchronism detection, Output side earth (ground) fault overcurrent, Stall prevention, Undervoltage Protection, Communication option fault, External thermal relay operation, Output phase loss, Output short circuit, PTC thermistor operation, Abnormal output current detection, CPU fault, Operation panel power supply short circuit/RS-485 terminals power supply short circuit, Option fault, Parameter storage device fault, Power fault, PU disconnection, Retry count excess, Analog input fault, Brake sequence fault, Communication fault (inverter), Encoder phase fault, Excessive position fault, Input fault, Inrush current limit circuit fault, Overspeed occurrence, Safety circuit fault, Signal loss detection, Speed deviation excess detection, USB communication fault, Abnormal internal temperature, Internal circuit fault, Magnetic pole position unknown, PID signal fault, Pre-charge fault […]
|
||
Điều khiển động cơ
|
||
RS485
|
||
CC-link, Modbus RTU, Profibus-DP
|
||
RS485
|
||
Screw terminal
|
||
Wall-panel mounting
|
||
Yes
|
||
Trong nhà
|
||
-10…50°C
|
||
90% max.
|
||
15kg
|
||
250mm
|
||
400mm
|
||
190mm
|
||
IP20
|
||
CCS, CE, cUL, KC, NK, RoHS, UL
|
document_fr-a800-series-mitsubishi-bien-tan-cao-cap-hieu-nang-va-chat-luong-vuot-troi-6656-catalog1